Your browser doesn't support javascript.
loading
: 20 | 50 | 100
1 - 20 de 115
1.
Neth Heart J ; 2024 Apr 23.
Article En | MEDLINE | ID: mdl-38653922

BACKGROUND: During transcatheter aortic valve implantation (TAVI), secondary access is required for angiographic guidance and temporary pacing. The most commonly used secondary access sites are the femoral artery (angiographic guidance) and the femoral vein (temporary pacing). An upper extremity approach using the radial artery and an upper arm vein instead of the lower extremity approach using the femoral artery and femoral vein may reduce clinically relevant secondary access site-related bleeding complications, but robust evidence is lacking. TRIAL DESIGN: The TAVI XS trial is a multicentre, randomised, open-label clinical trial with blinded evaluation of endpoints. A total of 238 patients undergoing transfemoral TAVI will be included. The primary endpoint is the incidence of clinically relevant bleeding (i.e. Bleeding Academic Research Consortium (BARC) type 2, 3 or 5 bleeding) of the randomised secondary access site (either diagnostic or pacemaker access, or both) within 30 days after TAVI. Secondary endpoints include time to mobilisation after TAVI, duration of hospitalisation, any BARC type 2, 3 or 5 bleeding, and early safety at 30 days according to Valve Academic Research Consortium­3 criteria. CONCLUSION: The TAVI XS trial is the first randomised trial comparing an upper extremity approach to a lower extremity approach with regard to clinically relevant secondary access site-related bleeding complications. The results of this trial will provide important insights into the safety and efficacy of an upper extremity approach in patients undergoing transfemoral TAVI.

2.
J Clin Med ; 13(3)2024 Jan 23.
Article En | MEDLINE | ID: mdl-38337345

Background The femoral vein is commonly used as a pacemaker access site during transcatheter aortic valve replacement (TAVR). Using an upper arm vein as an alternative access site potentially causes fewer bleeding complications and shorter time to mobilization. We aimed to assess the safety and efficacy of an upper arm vein as a temporary pacemaker access site during TAVR. Methods We evaluated all patients undergoing TAVR in our center between January 2020 and January 2023. Upper arm, femoral, and jugular vein pacemaker access was used in 255 (45.8%), 191 (34.3%), and 111 (19.9%) patients, respectively. Clinical outcomes were analyzed according to pacemaker access in the overall population and in a propensity-matched population involving 165 upper arm and 165 femoral vein patients. Primary endpoint was Bleeding Academic Research Consortium (BARC) type 2, 3, or 5 pacemaker access site-related bleeding. Results In the overall population, primary endpoint was lowest for upper arm, followed by femoral and jugular vein access (2.4% vs. 5.8% vs. 10.8%, p = 0.003). Time to mobilization was significantly longer (p < 0.001) in the jugular cohort compared with the other cohorts. In the propensity-matched cohort, primary endpoint showed a trend toward lower occurrence in the upper arm compared with the femoral cohort (2.4% vs. 6.1%, p = 0.10). Time to mobilization was significantly shorter (480 vs. 1140 min, p < 0.001) in the upper arm cohort, with a comparable skin-to-skin time (83 vs. 85 min, p = 0.75). Cross-over from upper arm pacemaker access was required in 17 patients (6.3% of attempted cases via an upper arm vein). Conclusions Using an upper arm vein as a temporary pacemaker access site is safe and feasible. Its use might be associated with fewer bleeding complications and shorter time to mobilization compared with the femoral vein.

3.
Article En | MEDLINE | ID: mdl-38376439

This case report is a step-by-step description of the surgical treatment of a giant right coronary aneurysm with a maximum diameter of 80 mm in a 57-year-old male.


Coronary Aneurysm , Male , Humans , Middle Aged , Coronary Aneurysm/diagnosis , Coronary Aneurysm/surgery
4.
J Am Heart Assoc ; 13(1): e029258, 2024 Jan 02.
Article En | MEDLINE | ID: mdl-38156593

BACKGROUND: Acute type B aortic dissection is a cardiovascular emergency with considerable mortality and morbidity risk. Male-female differences have been observed in cardiovascular disease; however, literature on type B aortic dissection is scarce. METHODS AND RESULTS: A retrospective cohort study was conducted including all consecutive patients with acute type B aortic dissection between 2007 and 2017 in 4 tertiary hospitals using patient files and questionnaires for late morbidity. In total, 384 patients were included with a follow-up of 6.1 (range, 0.02-14.8) years, of which 41% (n=156) were female. Women presented at an older age than men (67 [interquartile range (IQR), 57-73] versus 62 [IQR, 52-71]; P=0.015). Prior abdominal aortic aneurysm (6% versus 15%; P=0.009), distally extending dissections (71 versus 85%; P=0.001), and clinical malperfusion (18% versus 32%; P=0.002) were less frequently observed in women. Absolute maximal descending aortic diameters were smaller in women (36 [IQR: 33-40] mm versus 39 [IQR, 36-43] mm; P<0.001), while indexed for body surface area diameters were larger in women (20 [IQR, 18-23] mm/m2 versus 19 [IQR, 17-21] mm/m2). No male-female differences were found in treatment choice; however, indications for invasive treatment were different (P<0.001). Early mortality rate was 9.6% in women and 11.8% in men (P=0.60). The 5-year survival was 83% (95% CI, 77-89) for women and 84% (95% CI, 79-89) for men (P=0.90). No male-female differences were observed in late (re)interventions. CONCLUSIONS: No male-female differences were found in management, early or late death, and morbidity in patients presenting with acute type B aortic dissection, despite distinct clinical profiles at presentation. More details on the impact of age and type of intervention are warranted in future studies.


Aortic Aneurysm, Thoracic , Aortic Dissection , Blood Vessel Prosthesis Implantation , Endovascular Procedures , Humans , Male , Female , Aortic Aneurysm, Thoracic/surgery , Retrospective Studies , Treatment Outcome , Aortic Dissection/epidemiology , Acute Disease , Risk Factors
5.
Nat Commun ; 14(1): 7994, 2023 Dec 02.
Article En | MEDLINE | ID: mdl-38042913

Aortic aneurysms, which may dissect or rupture acutely and be lethal, can be a part of multisystem disorders that have a heritable basis. We report four patients with deficiency of selenocysteine-containing proteins due to selenocysteine Insertion Sequence Binding Protein 2 (SECISBP2) mutations who show early-onset, progressive, aneurysmal dilatation of the ascending aorta due to cystic medial necrosis. Zebrafish and male mice with global or vascular smooth muscle cell (VSMC)-targeted disruption of Secisbp2 respectively show similar aortopathy. Aortas from patients and animal models exhibit raised cellular reactive oxygen species, oxidative DNA damage and VSMC apoptosis. Antioxidant exposure or chelation of iron prevents oxidative damage in patient's cells and aortopathy in the zebrafish model. Our observations suggest a key role for oxidative stress and cell death, including via ferroptosis, in mediating aortic degeneration.


Aortic Aneurysm , Zebrafish , Humans , Male , Mice , Animals , Selenocysteine , Muscle, Smooth, Vascular/metabolism , Aortic Aneurysm/genetics , Aortic Aneurysm/metabolism , Selenoproteins/genetics , Myocytes, Smooth Muscle/metabolism
6.
Article En | MEDLINE | ID: mdl-37917572

A distal anastomosis in zone 3 is technically demanding during the frozen elephant trunk procedure. Proximalization of the distal anastomosis to zone 2 with subsequent revascularization of the left subclavian artery is an attractive alternative. This video tutorial describes the technique of an extra-anatomical bypass from the aortic prosthesis to the infraclavicular left subclavian (axillary) artery in arch replacement with the distal aortic graft anastomosis in zone 2.


Aortic Aneurysm, Thoracic , Aortic Dissection , Blood Vessel Prosthesis Implantation , Humans , Subclavian Artery/surgery , Aortic Aneurysm, Thoracic/surgery , Stents , Blood Vessel Prosthesis Implantation/methods , Treatment Outcome , Aorta, Thoracic/surgery , Blood Vessel Prosthesis
7.
Eur J Vasc Endovasc Surg ; 66(6): 784-796, 2023 12.
Article En | MEDLINE | ID: mdl-37330201

OBJECTIVE: Pre-procedural planning of thoracic endovascular aortic repair (TEVAR) may implement computational adjuncts to predict technical and clinical outcomes. The aim of this scoping review was to explore the currently available TEVAR procedure and stent graft modelling options. DATA SOURCES: PubMed (MEDLINE), Scopus, and Web of Science were systematically searched (English language, up to 9 December 2022) for studies presenting a virtual thoracic stent graft model or TEVAR simulation. REVIEW METHODS: The Preferred Reporting Items for Systematic Reviews and Meta-Analyses Extension for Scoping Reviews (PRISMA-ScR) was followed. Qualitative and quantitative data were extracted, compared, grouped, and described. Quality assessment was performed using a 16 item rating rubric. RESULTS: Fourteen studies were included. Among the currently available in silico simulations of TEVAR, severe heterogeneity exists in study characteristics, methodological details, and evaluated outcomes. Ten studies (71.4%) were published during the last five years. Eleven studies (78.6%) included heterogeneous clinical data to reconstruct patient specific aortic anatomy and disease (e.g., type B aortic dissection, thoracic aortic aneurysm) from computed tomography angiography imaging. Three studies (21.4%) constructed idealised aortic models with literature input. The applied numerical methods consisted of computational fluid dynamics analysing aortic haemodynamics in three studies (21.4%) and finite element analysis analysing structural mechanics in the others (78.6%), including or excluding aortic wall mechanical properties. The thoracic stent graft was modelled as two separate components (e.g., graft, nitinol) in 10 studies (71.4%), as a one component homogenised approximation (n = 3, 21.4%), or including nitinol rings only (n = 1, 7.1%). Other simulation components included the catheter for virtual TEVAR deployment and numerous outcomes (e.g., Von Mises stresses, stent graft apposition, drag forces) were evaluated. CONCLUSION: This scoping review identified 14 severely heterogeneous TEVAR simulation models, mostly of intermediate quality. The review concludes there is a need for continuous collaborative efforts to improve the homogeneity, credibility, and reliability of TEVAR simulations.


Aortic Aneurysm, Thoracic , Blood Vessel Prosthesis Implantation , Endovascular Procedures , Humans , Blood Vessel Prosthesis , Endovascular Aneurysm Repair , Aorta, Thoracic/diagnostic imaging , Aorta, Thoracic/surgery , Stents , Blood Vessel Prosthesis Implantation/adverse effects , Blood Vessel Prosthesis Implantation/methods , Reproducibility of Results , Endovascular Procedures/adverse effects , Endovascular Procedures/methods , Postoperative Complications/surgery , Treatment Outcome , Aortic Aneurysm, Thoracic/diagnostic imaging , Aortic Aneurysm, Thoracic/surgery , Retrospective Studies
8.
Neth Heart J ; 31(10): 383-389, 2023 Oct.
Article En | MEDLINE | ID: mdl-37256540

BACKGROUND: Postsurgical thoracic aortic pseudoaneurysms (PTAPs) are a potentially lethal complication after cardiac or aortic surgery. Surgical management can pose a challenge with high in-hospital mortality rates. Transcatheter closure is a less-invasive alternative treatment option for selected patients, although current experience is limited. AIMS: We aimed to evaluate procedural and imaging outcomes of our first 11 cases of transcatheter PTAP closure with the use of closure devices. METHODS: Patients with a high operative risk who underwent transcatheter PTAP closure at our centre from 2019 to 2021 were retrospectively included. Suitability was evaluated on preprocedural computed tomography (CT) scans and three-dimensional (3D) reconstructions. All procedures were performed in the catheterisation laboratory. Intraprocedural aortography and postprocedural CT scans with 3D reconstructions were used to evaluate PTAP occlusion. RESULTS: Eleven consecutive patients with a high operative risk and a history of cardiac/aortic surgery who underwent transcatheter PTAP closure were included. PTAPs were predominantly located at the proximal or distal anastomosis of a supracoronary ascending aortic vascular graft or Bentall prosthesis (82%). Implanted closure devices included Amplatzer Valvular Plug III (82%), Amplatzer septal occluder (9%) and Occlutech atrial septal defect occluder (9%). No periprocedural complications occurred. After device deployment, residual flow was absent on aortography in 64% and minimal residual flow was present in 36% of patients. Subtotal or total occlusion of the PTAP on follow-up CT ranged between 45% and 73%. CONCLUSIONS: Although subtotal or total occlusion of the PTAP was found at follow-up in only 45-73% of cases, transcatheter PTAP closure guided by preprocedural 3D reconstructions can offer a valuable minimally invasive primary treatment option for patients who otherwise would face a high-risk reoperation.

9.
Eur J Vasc Endovasc Surg ; 66(3): 332-341, 2023 09.
Article En | MEDLINE | ID: mdl-37245796

OBJECTIVE: Acute type B aortic dissection (ATBD) is a rare yet serious cardiovascular event that potentially has an impact on health related quality of life (HRQoL). However, long term follow up data on this topic are scarce. This study aimed to review the long term HRQoL among patients treated for ATBD. METHODS: In this multicentre, cross sectional survey study, consecutive treated patients with ATBD between 2007 and 2017 in four referral centres in the Netherlands were retrospectively included and baseline data were collected. Between 2019 and 2021 the 36 Item Short Form Survey (SF-36) was sent to all surviving patients (n = 263) and was compared with validated SF-36 scores in the Dutch general population stratified by age and sex. RESULTS: In total, 144 of 263 surviving patients completed the SF-36 (response rate 55%). Median (IQR) age was 68 (61, 76) years at completion of the questionnaire, and 40% (n = 58) were female. Initial treatment was medical in 55% (n = 79), endovascular in 41% (n = 59), and surgical in 4% (n = 6) of ATBD patients. Median follow up time was 6.1 (range 1.7-13.9; IQR 4.0, 9.0) years. Compared with the general population, patients scored significantly worse on six of eight SF-36 subdomains, particularly physical domains. Apart from bodily pain, there were no substantial differences in HRQoL between male and female ATBD patients. Compared with sex matched normative data, females scored significantly worse on five of eight subdomains, whereas males scored significantly lower on six subdomains. Younger patients aged 41-60 years seemed more severely impaired in HRQoL compared with the age matched general population. Treatment strategy did not influence HRQoL outcomes. Follow up time was associated with better Physical and Mental Component Summary scores. CONCLUSION: Long term HRQoL was impaired in ATBD patients compared with the Dutch general population, especially regarding physical status. This warrants more attention for HRQoL during clinical follow up. Rehabilitation programmes including exercise and physical support might improve HRQoL and increase patients' health understanding.


Aortic Dissection , Quality of Life , Humans , Male , Female , Cross-Sectional Studies , Retrospective Studies , Surveys and Questionnaires , Aortic Dissection/surgery
10.
Front Cardiovasc Med ; 10: 1127685, 2023.
Article En | MEDLINE | ID: mdl-37057097

Background: Bicuspid aortic valve (BAV) is associated with ascending aorta aneurysms and dissections. Presently, genetic factors and pathological flow patterns are considered responsible for aneurysm formation in BAV while the exact role of inflammatory processes remains unknown. Methods: In order to objectify inflammation, we employ a highly sensitive, quantitative immunohistochemistry approach. Whole slides of dissected, dilated and non-dilated ascending aortas from BAV patients were quantitatively analyzed. Results: Dilated aortas show a 4-fold increase of lymphocytes and a 25-fold increase in B lymphocytes in the adventitia compared to non-dilated aortas. Tertiary lymphoid structures with B cell follicles and helper T cell expansion were identified in dilated and dissected aortas. Dilated aortas were associated with an increase in M1-like macrophages in the aorta media, in contrast the number of M2-like macrophages did not change significantly. Conclusion: This study finds unexpected large numbers of immune cells in dilating aortas of BAV patients. These findings raise the question whether immune cells in BAV aortopathy are innocent bystanders or contribute to the deterioration of the aortic wall.

11.
Eur J Cardiothorac Surg ; 63(6)2023 06 01.
Article En | MEDLINE | ID: mdl-37052672

OBJECTIVES: The aim of this study was to examine whether perioperative changes in cerebral blood flow (CBF) relate to postoperative neurological deficits in patients undergoing aortic arch surgery involving antegrade selective cerebral perfusion (ASCP). METHODS: We retrospectively analysed data from patients who underwent aortic arch surgery involving ASCP and perioperative transcranial Doppler assessments. Linear mixed-model analyses were performed to examine perioperative changes in mean bilateral blood velocity in the middle cerebral arteries, reflecting changes in CBF, and their relation with neurological deficits, i.e. ischaemic stroke and/or delirium. Logistic regression analyses were performed to explore possible risk factors for postoperative neurological deficits. RESULTS: In our study population (N = 102), intraoperative blood velocities were lower compared to preoperative levels, and lowest during ASCP. Thirty-six (35%) patients with postoperative neurological deficits (ischaemic stroke, n = 9; delirium, n = 25; both, n = 2) had lower blood velocity during ASCP compared to patients without (25.4 vs 37.0 cm/s; P = 0.002). Logistic regression analyses revealed lower blood velocity during ASCP as an independent risk factor for postoperative neurological deficits (odds ratio = 0.959; 95% confidence interval: 0.923, 0.997; P = 0.037). CONCLUSIONS: Lower intraoperative CBF during ASCP seems independently related to postoperative neurological deficits in patients undergoing aortic arch surgery. Because CBF is a modifiable factor during ASCP, our observation has significant potential to improve clinical management and prevent neurological deficits.


Aortic Aneurysm, Thoracic , Brain Ischemia , Delirium , Ischemic Stroke , Stroke , Humans , Aorta, Thoracic/diagnostic imaging , Aorta, Thoracic/surgery , Brain Ischemia/etiology , Brain Ischemia/prevention & control , Retrospective Studies , Stroke/etiology , Stroke/prevention & control , Perfusion , Cerebrovascular Circulation/physiology , Treatment Outcome , Postoperative Complications/prevention & control , Aortic Aneurysm, Thoracic/surgery
12.
Cardiovasc Diagn Ther ; 13(1): 61-66, 2023 Feb 28.
Article En | MEDLINE | ID: mdl-36864965

For years, the elephant trunk (ET) technique has been applied to extended aortic arch pathology facilitating staged downstream open- or endovascular completion. The recent use of a stentgraft as so-called frozen ET enables even single-stage repair, or its use as a scaffold in an acutely or chronically dissected aorta. Hybrid prosthesis have since been introduced, available as either a 4-branch graft or a straight graft for reimplantation of the arch vessels using the classic island technique. Both techniques are known to have technical advantages and disadvantages in specific surgical scenarios. In this paper we will discuss whether a 4-branch graft hybrid prosthesis is advantageous over a straight hybrid prosthesis. Our considerations in terms of mortality, cerebral embolic risk, myocardial ischemia time, cardiopulmonary bypass (CPB) time, hemostasis and exclusion of supra-aortic entries in the case of acute dissection will be shared. The 4-branch graft hybrid prosthesis conceptually facilitates reduced systemic-, cerebral-, and cardiac arrest time. Additionally, atherosclerotic ostial debris, intimal re-entries, and fragile aortic tissue in genetic disease can be excluded by using a branched graft instead of the island technique for reimplantation of the arch vessels. Despite many conceptual technical advantages of the 4-branch graft hybrid prosthesis, literature data do not show significantly better outcomes when compared to the straight graft, to support its routine use in all cases.

13.
Eur Heart J Case Rep ; 7(3): ytad099, 2023 Mar.
Article En | MEDLINE | ID: mdl-36926264

Background: Percutaneous patent foramen ovale (PFO) closure is considered safe and has been used widely for over 25 years. A rare but potentially life-threatening complication is device migration, especially to the aorta. Case summary: We present a 30-year-old male with a PFO occlusion device implanted for cryptogenic stroke, which asymptomatically migrated to the aortic arch. A percutaneous retrieval attempt failed at complete removal but relocated the device to the proximal descending aorta. It was then successfully removed by open surgery. Severe intimal damage necessitated resection and interposition grafting. Discussion: Manipulation of migrated intravascular devices can cause intimal damage and subsequent complications, such as local dissections. We advocate caution with percutaneous removal of such large, migrated closure devices to avoid additional intimal damage, especially after endothelialization has occurred. The interventional cardiologist should be aware of the risk of intimal damage as a result, and surgical removal, though invasive, should always be considered.

14.
J Cardiovasc Surg (Torino) ; 64(2): 134-141, 2023 Apr.
Article En | MEDLINE | ID: mdl-36987816

BACKGROUND: For descending thoracic aortic aneurysms (TAA) in proximity of the aortic arch, debranching of the left subclavian artery (LSA) may be necessary to extend proximal sealing in zone 2. The aim of this study was to determine the added proximal apposition length gained from LSA debranching during thoracic endovascular aortic repair (TEVAR). METHODS: This multicenter retrospective study (2010-2020) included patients who underwent elective TEVAR in zone 2 for a degenerative TAA where the LSA was surgically debranched. The endograft position on the first postoperative computed tomography angiography (CTA) scan was assessed using post-processing software. The analysis included the shortest apposition length (SAL), the tilt of the proximal edge of the endograft, and the distance between the endograft and the left common carotid artery. Clinical endpoints (neurological complications and endoleaks) at 30 days were also reported. RESULTS: Twenty-two patients were included. The median interval between TEVAR and the first postoperative CTA was 3 days (2-10 days). Median SAL was 9.2 mm (1.3-26.4 mm), of which 8.6 mm (1.3-16.2 mm) was gained proximal of the LSA, including the LSA orifice. In 12 patients (55.5%) the SAL was <10 mm. The median tilt was 18.3° (13.9°-22.2°). Seven endoleaks were reported on the first CTA: 1 type Ia, 2 type Ib, 3 type II, and 1 type III. CONCLUSIONS: Debranching the LSA adds valuable sealing length in zone 2, but the SAL was still relatively short in many patients, putting these patients at risk for a future type Ia endoleak. Accurate assessment of the circumferential apposition on postoperative CTA follow-up in these high-risk patients with short, complex landing zones seems mandatory. Evaluation of apposition in a larger population with longer follow-up is advised.


Aortic Aneurysm, Thoracic , Blood Vessel Prosthesis Implantation , Endovascular Procedures , Humans , Aorta, Thoracic/diagnostic imaging , Aorta, Thoracic/surgery , Blood Vessel Prosthesis/adverse effects , Blood Vessel Prosthesis Implantation/adverse effects , Blood Vessel Prosthesis Implantation/methods , Endovascular Aneurysm Repair , Endoleak/diagnostic imaging , Endoleak/etiology , Endoleak/surgery , Subclavian Artery/diagnostic imaging , Subclavian Artery/surgery , Retrospective Studies , Treatment Outcome , Aortography/methods , Endovascular Procedures/adverse effects , Endovascular Procedures/methods , Aortic Aneurysm, Thoracic/diagnostic imaging , Aortic Aneurysm, Thoracic/surgery , Aortic Aneurysm, Thoracic/complications
15.
Vascular ; 31(3): 455-462, 2023 Jun.
Article En | MEDLINE | ID: mdl-35225085

OBJECTIVE: To describe mid-term outcomes of the use of EndoAnchors as an adjunct for arch and thoracic endovascular aortic repair (TEVAR). METHODS: A retrospective multicentre series from nine centres using the Heli-FX EndoAnchor System (Medtronic Inc, Minneapolis, USA) at TEVAR over May 2014-May 2019 is presented. The study is registered at ClinicalTrials.gov with number NCT04100499. The primary outcome was freedom from Type I endoleak at EndoAnchors deployments; secondary outcomes included evaluation of aortic wall penetration (AWP) at first computed tomography scan, EndoAnchor-related issues and mortality. RESULTS: 54 high-risk patients (35 males/19 females, age 73 ± 11 years) with arch, thoracic and thoracoabdominal aneurysmal disease (3 chronic post-dissection and one patch pseudoaneurysm), with a mean neck length 19.7 ± 6.6 mm that were treated with multiple hybrid and endovascular techniques were included. A total of 329 EndoAnchors were used with a mean of 6.1 ± 2.5 per patient. Overall adequate AWP was 86%, whereas arch (Ishimaru's zones 0-2) deployments achieved 80.6% when compared to 87.3% in descending thoracic aorta (dTA); although there was no statistical significance. Freedom from type I endoleaks was 88% at 2 year follow-up, due to 4 type IA endoleaks, two of them successfully treated, one with conservative treatment due to complexity of repair and remaining patient died 1 year later due to endograft infection. There were reported five EndoAnchor-related issues; four losses and one renal stent-graft was crushed due to catheter deflection solved with balloon reinflation. None of the losses had clinical significance. Overall mortality is described for 7 (9.5%) patients, one of them aneurysm-related. CONCLUSIONS: The adjunctive use of EndoAnchors in TEVAR and complex TEVAR procedures achieved acceptable outcomes at midterm in a high-risk series with hostile seal zones. Still, they should be still judiciously used as there is lack of data to suggest a more liberal use; therefore, the landing zone should not be compromised in favour of their use.


Aortic Aneurysm, Thoracic , Blood Vessel Prosthesis Implantation , Endovascular Procedures , Male , Female , Humans , Middle Aged , Aged , Aged, 80 and over , Blood Vessel Prosthesis , Blood Vessel Prosthesis Implantation/adverse effects , Endovascular Aneurysm Repair , Endoleak/diagnostic imaging , Endoleak/etiology , Endoleak/surgery , Treatment Outcome , Endovascular Procedures/adverse effects , Retrospective Studies , Risk Factors , Aortic Aneurysm, Thoracic/diagnostic imaging , Aortic Aneurysm, Thoracic/surgery , Aortic Aneurysm, Thoracic/etiology
16.
Clin Appl Thromb Hemost ; 28: 10760296221144042, 2022.
Article En | MEDLINE | ID: mdl-36476152

Cardiovascular surgery is often complicated by significant bleeding due to perioperative coagulopathy. The effectiveness of treatment with fibrinogen concentrate to reduce the perioperative blood transfusion rate after thoracic aortic replacement surgery in prior studies has shown conflicting results. Therefore, we conducted a double-blind randomized controlled trial to investigate if a single dose of intraoperative fibrinogen administration reduced blood loss and allogeneic transfusion rate after elective surgery for thoracic arch aneurysm with deep hypothermic circulatory arrest. Twenty patients were randomized to fibrinogen concentrate (N = 10) or placebo (N = 10). The recruitment of study patients was prematurely ended due to a low inclusion rate. Perioperative transfusion, 5-minute bleeding mass after study medication and postoperative blood loss were not different between the groups with fibrinogen concentrate or placebo. Due to small volumes of postoperative blood loss and premature study termination, a beneficial effect of fibrinogen concentrate on the number of blood transfusions could not be established. However, treatment with fibrinogen efficiently restored fibrinogen levels and clot strength to preoperative values with a more effective preserved postoperative thrombin generation capacity. This result might serve as a pilot for further multicenter studies to assess the prospective significance of automated and standardized thrombin generation as a routine assay for monitoring perioperative coagulopathy and its impact on short- and long-term operative results.


Aorta, Thoracic , Fibrinogen , Humans , Fibrinogen/therapeutic use , Aorta, Thoracic/surgery , Thrombin , Prospective Studies , Blood Transfusion , Postoperative Hemorrhage
17.
J Endovasc Ther ; : 15266028221134889, 2022 Nov 07.
Article En | MEDLINE | ID: mdl-36342189

OBJECTIVE: Effectiveness of thoracic endovascular aortic repair in type B aortic dissection is impaired by persistent retrograde false lumen flow via distal re-entry tears. Controlled, stentgraft-assisted balloon dilatation of the true lumen at its lower end, or Knickerbocker technique, may block retrograde false lumen flow and consequently improve effectiveness by inducing immediate thrombosis along the entire descending thoracic aorta. MATERIALS AND METHODS: A single-center retrospective analysis was performed for all consecutive patients with aortic dissection treated with the Knickerbocker technique to block retrograde false lumen flow. RESULTS: Eleven patients were included for analysis. Intraoperative control angiography showed successful occlusion of the false lumen at the level of balloon dilatation in 9 out of 11 patients (82%). There was one perioperative mortality (9%), due to stroke. There were 2 early reinterventions, due to retroperitoneal bleeding and due to chyle leakage in the neck after left subclavian artery bypass. Median clinical follow-up duration was 6 (interquartile range [IQR] 2-11] months. There were 2 deaths during follow-up, one at 2 months after TEVAR from unknown cause of death, and one after 11 months due to rupture of an ascending aortic pseudoaneurysm. The Knickerbocker technique led to positive aortic remodeling. At 3 months follow-up, 100% of patients showed complete false lumen thrombosis in the thoracic aorta proximal to the level of balloon dilatation, with decreasing false lumen diameters (100%) and stable (44%) or decreasing (56%) total aortic diameters. In most patients, the false lumen distal to the stentgraft (i.e. at visceral level) remained patent (11% false lumen thrombosis rate), leading to ≥2 mm dilatation at this level (78% of patients) and in the infrarenal abdominal aorta (56% of patients) at 3 months postoperatively. No distal stent-graft-induced new entry tears were noticed during follow-up. CONCLUSION: The Knickerbocker technique is feasible and effective, leading to positive aortic remodeling of the aorta covered by stentgraft in all of a small cohort of patients. CLINICAL IMPACT: Persistent, retrograde false lumen perfusion from distal re-entries following thoracic endovascular aortic repair (TEVAR) for Stanford type B aortic dissection, may lead to progressive, aneurysmal dilatation. Controlled, stent graft-assisted balloon dilatation of the true lumen in the distal descending aorta (i.e. Knickerbocker technique) during TEVAR effectively excludes the false lumen from persistent flow resulting in positive aortic remodeling in our small cohort of patients, and hence potentially eliminates the risk of late post-dissection aneurysm formation in the descending thoracic aorta.

19.
J Vasc Surg Cases Innov Tech ; 8(3): 480-483, 2022 Sep.
Article En | MEDLINE | ID: mdl-36052209

We have presented a case of a ruptured descending aortic aneurysm that was accompanied by extreme tortuosity and a pseudocoarctation at the level of the ligamentum arteriosum. We performed successful endovascular repair, covering the left subclavian artery, using a transapical-to-femoral artery (through-and-through) guidewire technique to overcome the tortuosity, with the option to perform balloon angioplasty in the case of an increased gradient over the coarctation. In the present case report, we have underlined the role of close collaborations with aortic expertise centers.

20.
J Vasc Surg Cases Innov Tech ; 8(2): 167-170, 2022 Jun.
Article En | MEDLINE | ID: mdl-35391994

Patients presenting with a Stanford type A acute aortic dissection require immediate surgical treatment; however, up to 30% of patients are deemed inoperable. Here we describe a case of a patient with a complicated type A acute aortic dissection presenting with a severe impact of brain malperfusion. In contrast with open surgery, an emergent thoracic endovascular aortic repair was performed with a Gore cTAG 45 × 150 mm graft and an additional chimney graft Advanta V12 7 × 59 mm graft for the brachiocephalic trunk. After early extubation, unexpected complete neurological recovery was observed. A follow-up computed tomography scan demonstrated complete remodeling of the ascending aorta. This report underlines the potential of thoracic endovascular aortic repair as an alternative for immediate open surgical repair in case of high-risk or inoperable patients.

...